sick_scan2

Repository Summary

Checkout URI https://github.com/SICKAG/sick_scan2.git
VCS Type git
VCS Version master
Last Updated 2022-09-05
Dev Status DEVELOPED
CI status No Continuous Integration
Released RELEASED
Tags No category tags.
Contributing Help Wanted (0)
Good First Issues (0)
Pull Requests to Review (0)

Packages

Name Version
sick_scan2 0.1.9

README

IMPORTANT: This repository will not be maintained further. The sources have been completely transferred to the repository https://github.com/SICKAG/sick_scan_xd. The repository will be deleted after 12/31/2022 in 2023 without further notice.

sick_scan2

This stack provides a ROS2 driver for the SICK lidar sensors mentioned in the following list.

Remark

During the last years we have developed different repositories within the driver development with the projects sick_scan, sick_scan2 and sick_scan_base, with which many lidars and radars of our company can be used under ROS1, ROS2 and generically under C++. For harmonization, due to customer requests and to increase clarity, we decided to combine these developments in the future. As a result of this work, at the end of 2021 we have created the repository sick_scan_xd, where we will continue future developments. We recommend using this new repository for development so that you can continue to benefit from our improvements and additions to our drivers.

Table of contents

This stack provides a ROS2 driver for the SICK laser scanners mentioned in the following list.

Supported Hardware

This driver should work with all of the following products.

ROS Device Driver for SICK lidar sensors - supported scanner types:

device name part no. description tested?
TiM240 1104981 1 layer max. range: 10 m, ang. resol. 1.00 [deg], 240 [deg] ✔ [prototype]
    Scan-Rate: 14.5 Hz  
TiM551 1060445 1 layer max. range: 10 m, ang. resol. 1.00[deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM561 1071419 1 layer max. range: 10 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM571 1079742 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM781 1096807 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM781S 1096363 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
LMS511-10100 PRO e.g. 1046135 1 layer max. range: 80 m, ang. resol. 0.167 [deg] ✔ [stable]
    Scan-Rate: 100 Hz  
LMS1xx-Family e.g. 1041114 1 layer max. range: 28 m, ang. resol. 0.25 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
MRS1104 1081208 4 layer max. range: 64 m, ang. resol. 0.25 [deg] hor., 2.50 [deg] ver. ✔ [development]
    Scan-Rate: 50 Hz, 4x12.5 Hz  
LMS1104 1092445 1 layer max. range: 64 m, ang. resol. 0.25 [deg] ✔ [stable]
    Scan-Rate: 150 Hz, 4x37.5 Hz  
LDMRS   4 or 8 layer, max. range: 50/320 m, ang. resol. 0.025°/…/0.25 [deg] ✔ [development]
    Scan-Rate: 12.5-50 Hz  
LRS4000   1 layer, max. range: 130 m, ang. resol. 0.125/0.25/0.5 [deg] ✔ [development]
    Scan-Rate: 12.5-25 Hz  

Requirements

sick_scan2 has been developed and tested using Linux ROS-2 Foxy. It should be compatible with other ROS-2 versions (but not fully tested).

Start Node

See quick start for further hints.

Sopas Mode

This driver supports both COLA-B (binary) and COLA-A (ASCII) communication with the laser scanner. Binary mode is activated by default. Since this mode generates less network traffic. If the communication mode set in the scanner memory is different from that used by the driver, the scanner’s communication mode is changed. This requires a restart of the TCP-IP connection, which can extend the start time by up to 30 seconds. There are two ways to prevent this:

  1. [Recommended] Set the communication mode with the SOPAS ET software to binary and save this setting in the scanner’s EEPROM.
  2. Use the parameter “use_binary_protocol” to overwrite the default settings of the driver.
  3. Setting “use_binary_protocol” to “False” activates COLA-A and disables COLA-B (default)

    Known issue

    If the scanner has not been set to binary Sopas in the EEPROM, the automatic restart of the TCP-IP connection does not work after the protocol change. The driver stops in this state: Wrong SOPAS Mode

    Workaround

    restart the driver node.

Bugs and feature requests

  • Stability issues: Driver is experimental and brand new
  • Sopas protocol mapping: – All scanners: COLA-B (Binary)
  • Software should be further tested, documented and beautified

Troubleshooting

  1. Check Scanner IP by using fping or SOPAS ET under Windows
  2. Check Ethernet connection to scanner with netcat e.g. nc -z -v -w5 $SCANNERIPADDRESS 2112 . For further details about setting up the correct ip settings see IP configuration
  3. View node startup output wether the IP connection could be established
  4. Check the scanner status using the LEDs on the device. The LED codes are described in the above mentioned operation manuals.
  5. Further testing and troubleshooting informations can found in the file test/readme_testplan.txt
  6. If you stop the scanner in your debugging IDE or by other hard interruption (like Ctrl-C), you must wait until 60 sec. before the scanner is up and running again. During this time the MRS6124 reconnects twice. If you do not wait this waiting time you could see one of the following messages:
    • TCP connection error
    • Error-Message 0x0d
  7. Amplitude values in rviz: If you see only one color in rviz try the following: Set the min/max-Range of intensity display in the range [0…200] and switch on the intensity flag in the lauch file
  8. In case of network problems check your own ip address and the ip address of your laser scanner (by using SOPAS ET).

File truncated at 100 lines see the full file

Repo symbol

sick_scan2 repository

sick_scan2

Repository Summary

Checkout URI https://github.com/SICKAG/sick_scan2.git
VCS Type git
VCS Version 0.1.4
Last Updated 2019-10-23
Dev Status DEVELOPED
CI status No Continuous Integration
Released RELEASED
Tags No category tags.
Contributing Help Wanted (0)
Good First Issues (0)
Pull Requests to Review (0)

Packages

Name Version
sick_scan2 0.1.4

README

sick_scan2

This stack provides a ROS2 driver for the SICK lidar sensors mentioned in the following list.

Table of contents

This stack provides a ROS2 driver for the SICK TiM series of laser scanners mentioned in the following list.

Supported Hardware

This driver should work with all of the following products.

ROS Device Driver for SICK lidar sensors - supported scanner types:

device name part no. description tested?
TiM551 1060445 1 layer max. range: 10 m, ang. resol. 1.00[deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM561 1071419 1 layer max. range: 10 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM571 1079742 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM781 1096807 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM781S 1096363 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  

Start Node

See quick start for further hints.

Sopas Mode

This driver supports both COLA-B (binary) and COLA-A (ASCII) communication with the laser scanner. Binary mode is activated by default. Since this mode generates less network traffic. If the communication mode set in the scanner memory is different from that used by the driver, the scanner’s communication mode is changed. This requires a restart of the TCP-IP connection, which can extend the start time by up to 30 seconds. There are two ways to prevent this:

  1. [Recommended] Set the communication mode with the SOPAS ET software to binary and save this setting in the scanner’s EEPROM.
  2. Use the parameter “use_binary_protocol” to overwrite the default settings of the driver.
  3. Setting “use_binary_protocol” to “False” activates COLA-A and disables COLA-B (default)

    Known issue

    If the scanner has not been set to binary Sopas in the EEPROM, the automatic restart of the TCP-IP connection does not work after the protocol change. The driver stops in this state: Wrong SOPAS Mode

    Workaround

    restart the driver node.

Bugs and feature requests

  • Stability issues: Driver is experimental and brand new
  • Sopas protocol mapping: – All scanners: COLA-B (Binary)
  • Software should be further tested, documented and beautified

Troubleshooting

  1. Check Scanner IP by using fping or SOPAS ET under Windows
  2. Check Ethernet connection to scanner with netcat e.g. nc -z -v -w5 $SCANNERIPADDRESS 2112 . For further details about setting up the correct ip settings see IP configuration
  3. View node startup output wether the IP connection could be established
  4. Check the scanner status using the LEDs on the device. The LED codes are described in the above mentioned operation manuals.
  5. Further testing and troubleshooting informations can found in the file test/readme_testplan.txt
  6. If you stop the scanner in your debugging IDE or by other hard interruption (like Ctrl-C), you must wait until 60 sec. before the scanner is up and running again. During this time the MRS6124 reconnects twice. If you do not wait this waiting time you could see one of the following messages:
    • TCP connection error
    • Error-Message 0x0d
  7. Amplitude values in rviz: If you see only one color in rviz try the following: Set the min/max-Range of intensity display in the range [0…200] and switch on the intensity flag in the lauch file
  8. In case of network problems check your own ip address and the ip address of your laser scanner (by using SOPAS ET).
    • List of own IP-addresses: ifconfig grep “inet addr”
    • Try to ping scanner ip address (used in launch file)
  9. If the driver stops during init phase please stop the driver with ctrl-c and restart (could be caused due to protocol ASCII/Binary cola-dialect).

Support

  • In case of technical support please open a new issue. For optimal support, add the following information to your request:
    1. Scanner model name,
    2. Ros node startup log,
    3. Sopas file of your scanner configuration. The instructions at http://sickusablog.com/create-and-download-a-sopas-file/ show how to create the Sopas file.
  • In case of application support please use https://supportportal.sick.com .
  • Issue Handling: Issues, for which no reply was received from the questioner for more than 7 days, are closed by us because we assume that the user has solved the problem.

Installation

In the following instructions, replace <rosdistro> with the name of your ROS distro (e.g., dashing).

From source

```bash source /opt/ros/$ROS_DISTRO/setup.bash mkdir -p ~/sick_scan_ws/src/ cd ~/sick_scan_ws/src/

File truncated at 100 lines see the full file

Repo symbol

sick_scan2 repository

Repo symbol

sick_scan2 repository

sick_scan2

Repository Summary

Checkout URI https://github.com/SICKAG/sick_scan2.git
VCS Type git
VCS Version master
Last Updated 2022-09-05
Dev Status DEVELOPED
CI status No Continuous Integration
Released RELEASED
Tags No category tags.
Contributing Help Wanted (0)
Good First Issues (0)
Pull Requests to Review (0)

Packages

Name Version
sick_scan2 0.1.9

README

IMPORTANT: This repository will not be maintained further. The sources have been completely transferred to the repository https://github.com/SICKAG/sick_scan_xd. The repository will be deleted after 12/31/2022 in 2023 without further notice.

sick_scan2

This stack provides a ROS2 driver for the SICK lidar sensors mentioned in the following list.

Remark

During the last years we have developed different repositories within the driver development with the projects sick_scan, sick_scan2 and sick_scan_base, with which many lidars and radars of our company can be used under ROS1, ROS2 and generically under C++. For harmonization, due to customer requests and to increase clarity, we decided to combine these developments in the future. As a result of this work, at the end of 2021 we have created the repository sick_scan_xd, where we will continue future developments. We recommend using this new repository for development so that you can continue to benefit from our improvements and additions to our drivers.

Table of contents

This stack provides a ROS2 driver for the SICK laser scanners mentioned in the following list.

Supported Hardware

This driver should work with all of the following products.

ROS Device Driver for SICK lidar sensors - supported scanner types:

device name part no. description tested?
TiM240 1104981 1 layer max. range: 10 m, ang. resol. 1.00 [deg], 240 [deg] ✔ [prototype]
    Scan-Rate: 14.5 Hz  
TiM551 1060445 1 layer max. range: 10 m, ang. resol. 1.00[deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM561 1071419 1 layer max. range: 10 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM571 1079742 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM781 1096807 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
TiM781S 1096363 1 layer max. range: 25 m, ang. resol. 0.33 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
LMS511-10100 PRO e.g. 1046135 1 layer max. range: 80 m, ang. resol. 0.167 [deg] ✔ [stable]
    Scan-Rate: 100 Hz  
LMS1xx-Family e.g. 1041114 1 layer max. range: 28 m, ang. resol. 0.25 [deg] ✔ [stable]
    Scan-Rate: 15 Hz  
MRS1104 1081208 4 layer max. range: 64 m, ang. resol. 0.25 [deg] hor., 2.50 [deg] ver. ✔ [development]
    Scan-Rate: 50 Hz, 4x12.5 Hz  
LMS1104 1092445 1 layer max. range: 64 m, ang. resol. 0.25 [deg] ✔ [stable]
    Scan-Rate: 150 Hz, 4x37.5 Hz  
LDMRS   4 or 8 layer, max. range: 50/320 m, ang. resol. 0.025°/…/0.25 [deg] ✔ [development]
    Scan-Rate: 12.5-50 Hz  
LRS4000   1 layer, max. range: 130 m, ang. resol. 0.125/0.25/0.5 [deg] ✔ [development]
    Scan-Rate: 12.5-25 Hz  

Requirements

sick_scan2 has been developed and tested using Linux ROS-2 Foxy. It should be compatible with other ROS-2 versions (but not fully tested).

Start Node

See quick start for further hints.

Sopas Mode

This driver supports both COLA-B (binary) and COLA-A (ASCII) communication with the laser scanner. Binary mode is activated by default. Since this mode generates less network traffic. If the communication mode set in the scanner memory is different from that used by the driver, the scanner’s communication mode is changed. This requires a restart of the TCP-IP connection, which can extend the start time by up to 30 seconds. There are two ways to prevent this:

  1. [Recommended] Set the communication mode with the SOPAS ET software to binary and save this setting in the scanner’s EEPROM.
  2. Use the parameter “use_binary_protocol” to overwrite the default settings of the driver.
  3. Setting “use_binary_protocol” to “False” activates COLA-A and disables COLA-B (default)

    Known issue

    If the scanner has not been set to binary Sopas in the EEPROM, the automatic restart of the TCP-IP connection does not work after the protocol change. The driver stops in this state: Wrong SOPAS Mode

    Workaround

    restart the driver node.

Bugs and feature requests

  • Stability issues: Driver is experimental and brand new
  • Sopas protocol mapping: – All scanners: COLA-B (Binary)
  • Software should be further tested, documented and beautified

Troubleshooting

  1. Check Scanner IP by using fping or SOPAS ET under Windows
  2. Check Ethernet connection to scanner with netcat e.g. nc -z -v -w5 $SCANNERIPADDRESS 2112 . For further details about setting up the correct ip settings see IP configuration
  3. View node startup output wether the IP connection could be established
  4. Check the scanner status using the LEDs on the device. The LED codes are described in the above mentioned operation manuals.
  5. Further testing and troubleshooting informations can found in the file test/readme_testplan.txt
  6. If you stop the scanner in your debugging IDE or by other hard interruption (like Ctrl-C), you must wait until 60 sec. before the scanner is up and running again. During this time the MRS6124 reconnects twice. If you do not wait this waiting time you could see one of the following messages:
    • TCP connection error
    • Error-Message 0x0d
  7. Amplitude values in rviz: If you see only one color in rviz try the following: Set the min/max-Range of intensity display in the range [0…200] and switch on the intensity flag in the lauch file
  8. In case of network problems check your own ip address and the ip address of your laser scanner (by using SOPAS ET).

File truncated at 100 lines see the full file